Metl-Span’s CF Tuff-Cast™ profile is an appealing insulated metal panel given its appearance of finished precast concrete. The exterior surface of the concrete look exterior panel is a hard aggregated fiber reinforced polymer coating and is created with the factory-applied Tuff Cote® finish system, which offers an extremely durable, impact and abrasion-resistant coating that can withstand severe weather conditions.
The wall panel’s exterior provides your building with an attractive precast concrete building alternative while maintaining energy efficiency. Since the panels have a double tongue-and-groove joint system, the cost of labor is reduced significantly when a building is constructed. This joint system also creates a barrier that is air, vapor, and water resistant.
The CF Tuff-Cast profile is available in a variety of color options, along with either vertical or horizontal textures.
G-90 galvanized or AZ-50 aluminum-zinc coated steel in 24 and 22 Ga.
Interior Face
G-90 galvanized or AZ-50 aluminum-zinc coated steel in 26, 24 and 22 Ga.
Exterior Texture
Tuff Cote finish system —a hard aggregated fiber-reinforced polymer coating
Finishes
Applied Finishes, Igloo White
Joint
Offset double tongue-and-groove with extended metal shelf for positive face fastening
Length
8′-0″ to 40′-0″; see data sheet for specifics
Thickness
2″, 2 ½”, 3″, 4″, 5″, 6″
*For K-Factor calculations: see data sheet. **Based on ASTM C518, ASTM C1363 and thermal modeling +5″ and 6″ CF Tuff-Cast and Tuff Wall available in Mesa, nominal 1/8″ deep profile only
1. Metallic paint finishes will exhibit color shift, shade variances, striations and longitudinal patterning that are inherent characteristics and are not a product defect or cause for rejection.
2. All Metl-Span colors are formulated to provide maximum energy-efficiency and solar reflectivity. All standard available Premium I and Premium II colors have been formulated for maximum solar reflectance.
3. Prices vary by color, gauge and quantity of metal. Please contact your Metl-Span representative for complete information.
4. All colors shown are approximate actual finish colors displayed as accurately as possible.
5. Light Stone – Tuff Cote® does not match the Light Stone – Standard SP color offering.
All specifications and designs are subject to change without notice.
Load Span Tables
The Load Span Tables below are based on Allowable Stress Design (ASD). For loads calculated based on ASCE 7-10 (LRFD), please refer to section 2.4.1 of ASCE 7-10 for the applicable load combinations using Allowable Stress Design.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
TESTING: CF Tuff-Cast Insulated Metal Wall Panel
Test/Approval
Test Method
Test Title
Results
Fire US
ASTM E84
Surface Burning Characteristics of Building Materials
Flame spread <25, smoke developed <450
ASTM E119
Fire Tests of Building Construction Materials
One hour non-load bearing rating with two layers of Type X Gypsum Vertical or horizontal installation
FM 4880
Class 1 Fire Rating of Insulated Wall, Ceiling and Roof Panels
Product approved Exterior wall requires FM 4881 approval
NFPA 259
Test Method for Potential Heat of Building Materials
Potential heat of foam plastic insulation contained in the assembly tested in accordance with NFPA 285
NFPA 285-19
Evaluation of Fire Propagation Characteristics of Exterior Non-Load Bearing Wall Assemblies
Panel assembly met the requirements of the standard
NFPA 286
Standard Methods of Fire Tests for Evaluating Contribution of Wall and Ceiling Interior Finish to Room Fire Growth
Test specimen met the criteria of the IBC Section 803.1.2.1
Fire Canada
CAN/ULC S101
Fire Endurance Tests of Building Construction and Materials
One hour non-load bearing fire rating with two layers of Type X Gypsum
CAN/ULC S101
Fire Endurance Tests of Building Construction and Materials
Meets 15 minute stay-in-place requirements
CAN/ULC S102
Surface Burning Characteristics of Building Materials and Assemblies
Meets the National Building Code of Canada requirements
CAN/ULC S134
Fire Test of Exterior Wall Assemblies
Complies with the fire-spread and heat-flux limitations required by the National Building Code of Canada
CAN/ULC S138
Fire Growth of Insulated Building Panels in a Full-Scale Room Configuration
Met the criteria of the standard
Structural
ASTM E72
Standard Test Methods of Conducting Strength Tests of Panels for Building Construction
See load chart
Thermal Performance
ASTM C518
Steady-State Thermal Transmission Properties by Means of the Heat-Flow Meter Apparatus
K-Factor of 0.114 BTU.in/hr.ft2.°F at 35° F mean core
ASTM C1363
Thermal Performance of Building Materials and Envelope Assemblies
See Thermal Performance Guide
Air Infiltration
ASTM E283
Rate of Air Leakage Through Curtain Walls Under Specified Pressure Differences
<0.01 cfm/ft2 at 20 psf Vertical or horizontal installation
ASTM E2357
Air Leakage of Air Barrier Assemblies
<0.04 cfm/ft2 air infiltration rate at static pressure differential of 1.57 psf, after 2,000 cycles at +/- 16.71 psf Vertical or Horizontal installation; with and without penetrations
Water Infiltration
ASTM E331
Water Penetration of Exterior Walls by Uniform Static Air Pressure Differences
No uncontrolled leakage when tested to a static pressure of 20 psf Vertical or horizontal installation
Special Approval
Miami-Dade NOA
Product Approval for City of Miami and Dade County
Product has City of Miami and Dade County Notice of Acceptance
State of Florida
Product Approval for the State of Florida
Product has State of Florida approval
Related Projects
CSU Practice Facility
The new Colorado State University Indoor Practice Facility in Fort Collins, CO sports 39,000 sq. ft. of Metl-Span CF-42 Light Mesa insulated wall panels. The 2” panels were finished in Herring Bone on the exterior and Igloo White on the interior.
Insulated metal panels from Metl-Span cover the walls of the new Baseball Player Development Center and Clubhouse, providing an energy-efficient shell for all seasons.